beautypg.com

Special failure situations, 1 special error situations, 2 error messages when storage overflow occurs – Kontron AM4901 IPMI User Manual

Page 86

background image

IPMI Firmware User Guide

AM5901/AM4901

Page 86

ID: 1035-8760, Rev. 3.0

10.

Special Failure Situations

10.1

Special Error Situations

The following information provides assistance to users for special error situations:

• Health LED is red: refer to chapter 3.8.3.

• AMC module does not activate: cause: slots improperly configured: refer to chapter 3.1.1,

or the AMC's FRU data does not contain a Current Requirement Record

• MCH FRU data not readable: cause: Common Options corrupted: refer to chapter 6.1.1,

re-enter and protect

• Backplane FRU data not readable: Environmental Options corrupted: refer to chapter

6.2.1, re-enter and protect

• Timeout during module activation occurs (message "WARNING: ACTIVATION

TIMEOUT FOR MODULE IN SLOT… CHECK MODULE AND PARAMETERS!"). Please
refer to CLI command 'activopts', chapter 5.1.2 CLI Command List.

• An AMC module can't be activated because it does not contain a Current Requirement

Record in its FRU data or the current value is 0. Message "CURRENT REQUIREMENT
RECORD MISSING FOR MODULE IN SLOT… OR VALUE IS 0." Or message "NO
CARRIER POWER POLICY RECORD FOUND".

• An AMC module can't be activated because there is no related backplane FRU data.

Message "CARRIER ACTIVATION AND CURRENT DESCRIPTOR MISSING FOR
SLOT…".

• The MCH resets continuously after powering up. Probably the MCH runs in a rack of type

OM6060 or OM6040D. Please disable the Management Ethernet port. Refer to chapter
"11. Peculiarities and Restrictions for Releases" for R31.

10.2

Error Messages when Storage Overflow Occurs

When the backplane offers more data than the MCH is able to store, then one of the following
error messages may occur. This should not occur in "well known" racks. Please note that it
might be impossible to maintain all inserted AMC modules. The "0xnn" values indicated are the
currently implemented limits.

ERROR: CARRIER_PTP_CONNECTIVITY_RECORD: Max PtP Res Descr

exceeded >= 0x22

WARNING: CARRIER_PTP_CONNECTIVITY_RECORD: Max Port Descr

exceeded = 0x21

WARNING: CARRIER_ADDRESS_TABLE_RECORD: Max Carrier Table

exceeded = 0x10

WARNING: AMC_PTP_CONNECTIVITY_RECORD: Max AMC Channel Descr

exceeded = 0x16

WARNING: AMC_PTP_CONNECTIVITY_RECORD: Max AMC Link Descr

exceeded = 0x22

This manual is related to the following products: