IPMI Firmware User Guide

AM5901/AM4901

Page 30

ID: 1035-8760, Rev. 3.0

current-
opts

Shows which current mode is currently selected (auto or manu
or off). When manu mode is selected the manual parameters are
displayed as well.

R

auto|manu|off

Sets the current mode for selecting the current parameters:

auto: Follows the data in the FRU record "MicroTCA Carrier

Power Policy record".

manu: Use current values as being defined in the manu

parameters below.

off: No current limitations used.

manu



"maxCurrentOverride" defines the maximum current (hex
[100mA]) that the rack's power module is able to deliver.
"maxCurrent slot x" defines the maximum current (hex [100mA])
that is allowed to be consumed by a module in slot x.

eopts

Display the current environmental options as one hexadecimal
number and as a sequence of hexadecimal numbers

R

(hex)>

Set all environmental options as one hexadecimal number

R

Set one environmental option. For the related option designator
refer to the result of command 'eopts'. Only the first four charac-
ters of the designators being listed are used as option designa-
tors. For the option values refer to chapter 'environmental
options'.

R

fclock

Display the current states of the slot’s f-clock signals. States
may be ‘off’ or ‘on’ or ‘ssc’.
Note: on or ssc means that during E-keying the slot was
detected as a consumer of the rack’s clock. The clock type is
non ssc (on) or ssc. This command is only supported in racks
which have a switchable clock generator.

R

< slot 1 f-clock state>

< slot 6 f-clock state>

This command is only for tests: Set the state of the f-clock to
‘off’ or ‘on’ or ‘ssc’.

R

Table 6:

CLI Command List

Command

Parameters

Description

User

or

Root