Kontron AM4901 IPMI User Manual
Page 30
IPMI Firmware User Guide
AM5901/AM4901
Page 30
ID: 1035-8760, Rev. 3.0
current-
opts
Shows which current mode is currently selected (auto or manu
or off). When manu mode is selected the manual parameters are
displayed as well.
R
auto|manu|off
Sets the current mode for selecting the current parameters:
auto: Follows the data in the FRU record "MicroTCA Carrier
Power Policy record".
manu: Use current values as being defined in the manu
parameters below.
off: No current limitations used.
manu
…
"maxCurrentOverride" defines the maximum current (hex
[100mA]) that the rack's power module is able to deliver.
"maxCurrent slot x" defines the maximum current (hex [100mA])
that is allowed to be consumed by a module in slot x.
eopts
Display the current environmental options as one hexadecimal
number and as a sequence of hexadecimal numbers
R
Set all environmental options as one hexadecimal number
R
Set one environmental option. For the related option designator
refer to the result of command 'eopts'. Only the first four charac-
ters of the designators being listed are used as option designa-
tors. For the option values refer to chapter 'environmental
options'.
R
fclock
Display the current states of the slot’s f-clock signals. States
may be ‘off’ or ‘on’ or ‘ssc’.
Note: on or ssc means that during E-keying the slot was
detected as a consumer of the rack’s clock. The clock type is
non ssc (on) or ssc. This command is only supported in racks
which have a switchable clock generator.
R
< slot 1 f-clock state>
…
< slot 6 f-clock state>
This command is only for tests: Set the state of the f-clock to
‘off’ or ‘on’ or ‘ssc’.
R
Table 6:
CLI Command List
Command
Parameters
Description
User