3 set fan speed parameter, 4 get fan speed parameter, Set fan speed parameter – Kontron AM4901 IPMI User Manual
Page 66: Get fan speed parameter

IPMI Firmware User Guide
AM5901/AM4901
Page 66
ID: 1035-8760, Rev. 3.0
8.2.3
Set Fan Speed Parameter
This command writes the fan speed parameter to the related NV-Parameter, saves this to EE-
PROM, and forces the new fan speed. It works only if automatic temperature control is inactive.
8.2.4
Get Fan Speed Parameter
This command reads the current fan speed parameter.
COMMAND
LUN
NetFn
CMD
SetFansSpeedParameter
00h
OEM = 3Eh
24h
REQUEST DATA
Byte
Data Field
1
Kontron IANA LSB
2
Kontron IANA byte 2
3
Kontron IANA MSB
4
Fan speed level 0…0xf
RESPONSE DATA
Byte
Data Field
1
Completion Code
2
Kontron IANA LSB
3
Kontron IANA byte 2
4
Kontron IANA MSB
COMMAND
LUN
NetFn
CMD
GetFansSpeedParameter
00h
OEM = 3Eh
25h
REQUEST DATA
Byte
Data Field
1
Kontron IANA LSB
2
Kontron IANA byte 2
3
Kontron IANA MSB
RESPONSE DATA
Byte
Data Field
1
Completion Code
2
Kontron IANA LSB
3
Kontron IANA byte 2
4
Kontron IANA MSB
5
Fan speed level 0…0xf