8.2.5
Set Permanent Power Parameter
This command writes the permanent power parameter to the related NV-Parameter and saves it.
8.2.6
Get Permanent Power Parameter
This command gets the permanent power parameter from the related NV-Parameter.
COMMAND
LUN
NetFn
CMD
SetPermPwrParameter
00h
OEM = 3Eh
26h
REQUEST DATA
Byte
Data Field
1
Kontron IANA LSB
2
Kontron IANA byte 2
3
Kontron IANA MSB
4:7
Permanent power parameter. LSB first.
Note: AMC Slot 1 = bit 5
RESPONSE DATA
Byte
Data Field
1
Completion Code
2
Kontron IANA LSB
3
Kontron IANA byte 2
4
Kontron IANA MSB
COMMAND
LUN
NetFn
CMD
GetPermPwrParameter
00h
OEM = 3Eh
27h
REQUEST DATA
Byte
Data Field
1
Kontron IANA LSB
2
Kontron IANA byte 2
3
Kontron IANA MSB
RESPONSE DATA
Byte
Data Field
1
Completion Code
2
Kontron IANA LSB
3
Kontron IANA byte 2
4
Kontron IANA MSB
5:8
Permanent power parameter. LSB first.