11 set slot options parameter, 12 get slot options parameter – Kontron AM4901 IPMI User Manual
Page 70

IPMI Firmware User Guide
AM5901/AM4901
Page 70
ID: 1035-8760, Rev. 3.0
8.2.11
Set Slot Options Parameter
This command writes the common options parameter to the related NV-Parameter and saves it.
8.2.12
Get Slot Options Parameter
This command gets the common options parameter from the related NV-Parameter.
COMMAND
LUN
NetFn
CMD
SetSlotOptionsParameter
00h
OEM = 3Eh
2Ch
REQUEST DATA
Byte
Data Field
1
Kontron IANA LSB
2
Kontron IANA byte 2
3
Kontron IANA MSB
4:15
Slot options parameter for slots 1…12. Slot 1 first.
RESPONSE DATA
Byte
Data Field
1
Completion Code
2
Kontron IANA LSB
3
Kontron IANA byte 2
4
Kontron IANA MSB
COMMAND
LUN
NetFn
CMD
GetSlotOptionsParameter
00h
OEM = 3Eh
2Dh
REQUEST DATA
Byte
Data Field
1
Kontron IANA LSB
2
Kontron IANA byte 2
3
Kontron IANA MSB
RESPONSE DATA
Byte
Data Field
1
Completion Code
2
Kontron IANA LSB
3
Kontron IANA byte 2
4
Kontron IANA MSB
5:16
Slot options parameter for slots 1…12. Slot 1 first.