9 set common options parameter, 10 get common options parameter, Set common options parameter – Kontron AM4901 IPMI User Manual
Page 69
AM5901/AM4901
IPMI Firmware User Guide
ID: 1035-8760, Rev. 3.0
Page 69
8.2.9
Set Common Options Parameter
This command writes the common options parameter to the related NV-Parameter and saves it.
8.2.10
Get Common Options Parameter
This command gets the common options parameter from the related NV-Parameter.
COMMAND
LUN
NetFn
CMD
SetCommonOptionsParameter
00h
OEM = 3Eh
2Ah
REQUEST DATA
Byte
Data Field
1
Kontron IANA LSB
2
Kontron IANA byte 2
3
Kontron IANA MSB
4:7
Common options parameter. LSB first.
Note: AMC Slot 1 = bit 5
RESPONSE DATA
Byte
Data Field
1
Completion Code
2
Kontron IANA LSB
3
Kontron IANA byte 2
4
Kontron IANA MSB
COMMAND
LUN
NetFn
CMD
GetCommonOptionsParameter
00h
OEM = 3Eh
2Bh
REQUEST DATA
Byte
Data Field
1
Kontron IANA LSB
2
Kontron IANA byte 2
3
Kontron IANA MSB
RESPONSE DATA
Byte
Data Field
1
Completion Code
2
Kontron IANA LSB
3
Kontron IANA byte 2
4
Kontron IANA MSB
5:8
Common options parameter. LSB first.
Note: AMC Slot 1 = bit 5