16 get event driven temperature control parameter – Kontron AM4901 IPMI User Manual

Page 73

background image

AM5901/AM4901

IPMI Firmware User Guide

ID: 1035-8760, Rev. 3.0

Page 73

8.2.16

Get Event Driven Temperature Control Parameter

This command gets the parameters for the event driven temperature control.

COMMAND

LUN

NetFn

CMD

GetEventDrivenTemperatureControlParameter

00h

OEM = 3Eh

31h

REQUEST DATA

Byte

Data Field

1

Kontron IANA LSB

2

Kontron IANA byte 2

3

Kontron IANA MSB

RESPONSE DATA

Byte

Data Field

1

Completion Code

2

Kontron IANA LSB

3

Kontron IANA byte 2

4

Kontron IANA MSB

5

initialFanLevel

6

minFanLevel

7

coolingFanIncreaseTimeout

8

coolingFanDecreaseTimeout

9

fanLevelStepUp

10

fanLevelStepDown

11

normalStableTime LSB

12

normalStableTime MSB

This manual is related to the following products: