ID: 1035-8760, Rev. 3.0
8.2.15
Set Event Driven Temperature Control Parameter
This command sets the parameters for the event driven temperature control and saves them
to EEPROM.
COMMAND
LUN
NetFn
CMD
SetEventDrivenTemperatureControlParameter
00h
OEM = 3Eh
30h
REQUEST DATA
Byte
Data Field
1
Kontron IANA LSB
2
Kontron IANA byte 2
3
Kontron IANA MSB
4
initialFanLevel
5
minFanLevel
6
coolingFanIncreaseTimeout
7
coolingFanDecreaseTimeout
8
fanLevelStepUp
9
fanLevelStepDown
10
normalStableTime LSB
11
normalStableTime MSB
RESPONSE DATA