8.2.20
Get Priority Options Parameters
This command gets the currently active slot priority parameters and the related common op-
tions parameters.
Command
LUN
NetFn
CMD
CmdGetSlotPriosParameter (internal name)
00h
OEM = 3Eh
35h
REQUEST DATA
Byte
Data Field
1
Kontron IANA LSB
2
Kontron IANA byte 2
3
Kontron IANA MSB
RESPONSE DATA
Byte
Data Field
1
Completion Code
2
Kontron IANA LSB
3
Kontron IANA byte 2
4
Kontron IANA MSB
5
prioMode (refer to common options)
Please refer to command “Set Priority Parameters” above.
6:9
reserved=0
10:10
+12
Slot priority parameter values of 12 slots
Please refer to command “Set Priority Parameters” above.