24 get current options parameters – Kontron AM4901 IPMI User Manual
Page 80

IPMI Firmware User Guide
AM5901/AM4901
Page 80
ID: 1035-8760, Rev. 3.0
8.2.24
Get Current Options Parameters
This command gets the currently active slot activation and deactivation parameters and the re-
lated common options parameters.
Command
LUN
NetFn
CMD
CmdGetPwrMngConfigParameter (internal name)
00h
OEM = 3Eh
39h
REQUEST DATA
Byte
Data Field
1
Kontron IANA LSB
2
Kontron IANA byte 2
3
Kontron IANA MSB
RESPONSE DATA
Byte
Data Field
1
Completion Code
2
Kontron IANA LSB
3
Kontron IANA byte 2
4
Kontron IANA MSB
5
pwrMngMode (refer to common options)
Please refer to command “Set Current Options Parameters” above.
6:7
maxCurrentOverride [100mA]
Please refer to command “Set Current Options Parameters” above.
8:9
reserved=0
10:10
+12
Maximal allowed current consumption [100mA] for 12 slots.
Please refer to command “Slot Set Current Options Parameters” above.