8.2.24

Get Current Options Parameters

This command gets the currently active slot activation and deactivation parameters and the re-
lated common options parameters.

Command

LUN

NetFn

CMD

CmdGetPwrMngConfigParameter (internal name)

00h

OEM = 3Eh

39h

REQUEST DATA

Byte

Data Field

1

Kontron IANA LSB

2

Kontron IANA byte 2

3

Kontron IANA MSB

RESPONSE DATA

Byte

Data Field

1

Completion Code

2

Kontron IANA LSB

3

Kontron IANA byte 2

4

Kontron IANA MSB

5

pwrMngMode (refer to common options)
Please refer to command “Set Current Options Parameters” above.

6:7

maxCurrentOverride [100mA]
Please refer to command “Set Current Options Parameters” above.

8:9

reserved=0

10:10
+12

Maximal allowed current consumption [100mA] for 12 slots.
Please refer to command “Slot Set Current Options Parameters” above.