shAddrDevice
---
ID of the used mode for access to the shelf
address/carrier number
>3 = Undefined ID
3 = Shelf address/carrier number will
be read as byte at I2C address
0x7C (e.g. on OM6060). The value
will be inverted and 1 added (from
R28 on). Results in value 1…16.
Adjustable by back plane switch 2.1
… 2.4.
2 = Shelf address/carrier number will
be read as byte at I2C address
0x4C (e.g. on ELMA K1 and K2).
The value is the raw register con-
tents.
1 = Shelf address/carrier number will
be read as byte at I2C address
0x7C (e.g. on OM6062). The value
will be inverted and 1 added (from
R28 on). Results in value 1…16.
Normally defined by the appropriate
setting of a back plane switch. For
further information, refer to the
User Guide for the system in
question.
0 = No shelf address/carrier number
will be accessed
A, M
15
---
---
Reserved
---
14:12
ps1EnDevice
---
ID of the strategy to detect a seated AMC
module
>3 = Undefined ID
3 = Like 1 but with 4 slots
2 = Automatic detection by a Standard
MTCA intelligent power device
1 = Automatic detection by a
PCA8574A e.g. on OM6060 6 slots
0 = No automatic detection e.g. on
OM6062. Managed modules i.e.
slots have to be defined by e.g. CLI
command ‘slot’
A, M