8.2.19
Set Priority Options Parameters
This command sets the priority parameters and the related common options parameters and
saves them to EEPROM.
Command
LUN
NetFn
CMD
CmdSetSlotPriosParameter (internal name)
00h
OEM = 3Eh
34h
REQUEST DATA
Byte
Data Field
1
Kontron IANA LSB
2
Kontron IANA byte 2
3
Kontron IANA MSB
4
prioMode (refer to common options)
0=AUTO: Use parameters from back plane FRU data “MicroTCA Carrier Activation and
Power Management record”
1=MANU: Use Slot priority parameters (refer to below)
2=OFF: No priorities used. Activation and deactivation sequence is random.
5:8
reserved=0
9:9+12
Slot priority parameter values of 12 slots. Beginning with slot 1.
Use every priority value 1 … e.g. 6 only once. Low number = high priority.
Priorities for not existing slots e.g. 7…12 are void but shall be unique as well.
Bit 7 set additionally = uncoordinated slot, not member of sequence.
RESPONSE DATA
Byte
Data Field
1
Completion Code
2
Kontron IANA LSB
3
Kontron IANA byte 2
4
Kontron IANA MSB