23 set current options parameters – Kontron AM4901 IPMI User Manual
Page 79
AM5901/AM4901
IPMI Firmware User Guide
ID: 1035-8760, Rev. 3.0
Page 79
8.2.23
Set Current Options Parameters
This command sets the current parameters (limits) and the related common options parame-
ters and saves them to EEPROM.
Command
LUN
NetFn
CMD
CmdSetPwrMngConfigParameter (internal name)
00h
OEM = 3Eh
38h
REQUEST DATA
Byte
Data Field
1
Kontron IANA LSB
2
Kontron IANA byte 2
3
Kontron IANA MSB
4
pwrMngMode (refer to common options)
0=AUTO: Use parameters from back plane FRU data “MicroTCA Carrier Power Policy
record”
1=MANU: Use current options parameters (refer to below)
2=OFF: No current limits used.
5:6
maxCurrentOverride [100mA], LSB first.
Maximal current which the rack’s power supply is able to deliver.
7:8
reserved=0
9:9+12
Maximal allowed current consumption [100mA] for 12 slots. Beginning with slot 1. Values for
not existing slots e.g. 7…12 are void.
RESPONSE DATA
Byte
Data Field
1
Completion Code
2
Kontron IANA LSB
3
Kontron IANA byte 2
4
Kontron IANA MSB