Downloading data list to personal computer – CDI Torque MULTITEST Government User Manual
Page 60

4-12
Using the MULTITEST Toque Calbration System
5. Press ENTER to download the raw data list. The LED
display reads:
SENDING
6. Press ENTER again to return to measurements mode.
Downloading Data List to Personal Computer
1. Connect the accessory 2000-50-1 cable between the
MULTITEST OPTIONAL port and the computer COM
port. For additional information on setting up printer or
PC ports, refer to Chapter 3—Set Up and Programming
.
2. Set up your computer to receive serial communication.
Example:
If using an IBM compatible and Windows 95:
— Click on START—RUN to open the Terminal
program.
— Type TERMINAL.
— Press
3. Press RECALL DATA.
4. Press SEND/AUTO SEND. As shown in Figure 4-5, the
LCD display reads:
Download - upper line
+Date Time Raw - lower line, with the plus sign flashing
— To download the data list plus date-time stamp,
press ENTER. The LED display reads:
SENDING
— To download the raw data list, use right DIGIT to
select “Raw” on the LCD display. Then press
ENTER to download. The LED display reads:
SENDING
5. Press ENTER again to return to measurements mode.
6. Copy the data list to your chosen software.
Example:
If using an IBM compatible and Windows 95:
— Select EDIT—SELECT ALL, and then EDIT—COPY.
— Open the spreadsheet or data program being used.
— Select EDIT—PASTE in the program being used.