beautypg.com

Dell PowerEdge VRTX User Manual

Page 141

background image

5.

Check the network connector indicators on the network switch module:

If the link indicator displays an error condition, check all cable connections.

Try another connector on the external switch or hub.

If the activity indicator does not light, replace the network switch module.

6.

Using the switch management interface, verify the switch port properties. If the switch is configured correctly,

back up the switch configuration and replace the switch. See the switch module documentation for details.

7.

Ensure that the appropriate Network Daughter Card(s) (NDC) are installed in the server module(s). If the network

link indicator on the server module is green, then the server module has a valid link to the I/O module.

8.

Ensure that the appropriate operating system drivers are installed and that the protocol settings are configured to

ensure proper communication.
For more information on troubleshooting I/O modules and network issues, see Networking Guides at
en.community.dell.com/techcenter/networking.

141