Pressure Depth Sensor and Float Switch Installation 3-39
Gathering Parts and Supplies
Obtain the following supplies before installing the float switch(es)
to prevent costly delays.
Quantity
Description
ADS Part Number
1
FlowAlert monitor
6000-FAW or -FAL
1
monitor mounting bracket
I40-0003
1
1 float switch (no pressure)
6000-0015-xx (xx
represents the
cable length in feet)
2 float switches (no pressure)
6000-0025-xx (xx
represents the
cable length in feet)
2 float switches and pressure pigtail
6000-0026-xx (xx
represents the
cable length in feet)
1 float switch and pressure pigtail
6000-0027-xx (xx
represents the
cable length in feet)
1
direct connection cable
5000-0601
10
anchor cable tie
I05-0004
15
¼-
× 2 ¼-inch anchor bolt (with 7/16-
inch nut and washer)
I01-0002
Gathering Tools and Equipment
Gather the following tools for the installation:
Battery-powered hammer drill with assorted bits – including
the following, at a minimum:
3/8-inch x 4-inch (minimum length) masonry bit
¼-inch masonry bit (F35-0018)
5/16-inch carbide-tipped drill bit (include smaller bits)