ADS Environmental Services FlowAlert QR 775011 A2 User Manual
Page 55

3-32
ADS FlowAlert Manual
Quantity
Description
ADS Part Number
4
6-32
× 1-inch machine screw
I35-0004
4
6-32
× 5/16 inch nut
I15-0003
15
plastic push mounts
I01-0006
1
sensor mounting strap
700-100238-00
2. Gather the following tools and supplies:
Battery-powered hammer drill with assorted bits –
including the following, at a minimum:
3/8-inch x 4-inch (minimum length) masonry bit
¼-inch masonry bit (F35-0018)
5/16-inch carbide-tipped drill bit (include smaller bits)
4-pound hammer
Rubber mallet
Wrenches
Screwdrivers (flathead and Phillips head of assorted sizes)
3/8 – 16 thread tap
Diagonal wire cutters
Folding carpenter’s rule with a brass slide
Rubber stretch tape
3. Determine the appropriate location on the manhole or wet well
wall to mount the sensor.
4. Hold the pressure mounting strap (ADS p/n 700-100238-00)
vertically against the wall at the selected location, and mark the
wall through the top hole of the strap.