Gathering parts and supplies – ADS Environmental Services FlowAlert QR 775011 A2 User Manual
Page 44
![background image](/manuals/599711/44/background.png)
Pressure Depth Sensor and Float Switch Installation 3-21
Performing a special installation involves the following process:
Gathering the parts and supplies
Gathering the tools and equipment
Mounting the pressure depth sensor
Securing the cables to the band
Before beginning the installation, conduct a thorough investigation
of hydraulic and other site conditions. The hydraulics of a site
directly affect the monitor's ability to accurately measure flow
depth. In addition, measure the horizontal and vertical pipe
dimensions carefully.
Caution: Handle the pressure depth sensor and cable
with extreme care. The sensor and cable contain delicate
mechanisms and electronics. Keep sharp objects away
from sensor cable, and avoid stepping or placing heavy
objects on the cable during installation.
Gathering Parts and Supplies
Be sure to obtain the following supplies before performing a special
installation to prevent any costly delays. When ordering, specify
the FlowAlert monitor special installation hardware.
Quantity
Description
ADS Part Number
1
FlowAlert monitor
6000-FAW or -FAL
1
monitor mounting bracket
I40-0003
1
pressure depth sensor with two 4-
40 x 5/16-inch stainless steel
screws
3704-0010-40 (5 psi)
3704-0015-40 (15 psi)
3704-0016-40 (30 psi)
1
replacement dryer tube
3704-0032
1
direct connection cable
5000-0601
15
11-inch cable tie
I05-0003
25
4-inch cable tie
I05-0001
15
8-inch cable tie
I05-0002