Finger set installation instructions, Installation steps, Annual maintenance – Great Plains YP2425F-2470 Operator Manual User Manual

Page 99: Precautions, Installation steps annual maintenance

background image

Great Plains Manufacturing, Inc.

Table of Contents

Index

Maintenance and Lubrication

95

2014-07-14

Table of Contents

Index

401-406M

Finger Set Installation Instructions

Installation Steps

Great Plains recommends having the meter service
performed by a recognized professional repair facility,
such as a certified Meter Max representative. Improper
servicing will result in reduced meter performance.

If you choose to service them yourself, follow these
procedures when installing the finger sets.

Refer to Figure 129
11. Be sure the belt is oriented as shown in Figure 129.

12. Slide the finger set over the shaft and rotate

clockwise until it sits against the backing plate.

Note: You will hear a click.

13. Firmly press the finger set against the backing plate

while tightening the nut.

14. Tighten the nut until contact is made between the nut

and the finger set. Turn

1

4

to

1

2

flat (

1

24

to

1

12

of a

turn) (a flat is one of the six sides of the nut) after
contact is made. This equals about four inch- pounds
of torque on the nut.

15. Place the slotted nut cover on and carefully align the

slotted nut cover with the shaft hole. Insert the cotter
pin.

16. Rotate the finger set clockwise and make sure the

fingers open and close properly. Fingers should be
closed at the 8:00 to 2:00 position (exit hole) and
open at the 2:00 to 8:00 position.

Annual Maintenance

Finger sets should be inspected on an annual basis.
After cleaning, carefully inspect the fingers and springs
for wear or other abnormalities that may develop.
Excessive wear may disrupt singulation performance.

Precautions
1.

Make sure the finger set is properly torqued against
the backing plate. Improperly torqued finger sets
may disrupt seed singulation.

2.

Avoid seed treatments, additives, and other
chemicals when possible. They can cause meter
performance problems, premature wear to meter
parts, and may cause undesired chemical reaction or
deterioration to the finger sets. Always use Precision
Planting or Great Plains graphite when using seed
treatments, See “Seed Lubricants” on page 108.
Graphite from other sources may cause premature
wear.

3.

Always pay attention to your seed monitor, pay
attention to your operating manual, and monitor the
amount of seed you are planting compared to your
expectations. Always investigate abnormalities!

Figure 129

Finger Pickup Meter

22507