John blue ground drive pump, Hypro ground drive pump – Great Plains YP2425F-2470 Operator Manual User Manual
Page 64
60
YP2425 & YP2425F
Great Plains Manufacturing, Inc.
401-406M
2014-07-14
John Blue Ground Drive Pump
Refer to Figure 68
With newer Type 2 fertilizer systems, the pumps
driven by a ground contact wheel
. Fertilizer rate is
independent of seed rate. Fertilizer coarse rate is set by
a driving sprocket
on the ground drive assembly, and
fine rate is adjusted at the setting hub (dial)
pump.
Equipment Damage/Material Loss Risks:
The ground drive contact wheel and chain system will operate
whenever the planter is lowered and in motion. If planting
without fertilizing, the pump must not be allowed to run dry.
Disconnect the chain or remove a sprocket.
Note: When a Type 3 fertilizer system is installed, the
pump is mounted at the source (not on the planter),
usually on a tank cart.
For sprocket and dial settings, refer to the Seed Rate
manual.
Hypro Ground Drive Pump
Refer to Figure 69
With older Type 2 fertilizer systems, the pumps
driven by a ground contact wheel
. Fertilizer rate is
independent of seed rate. Fertilizer rate is set by
driving
and driven
sprockets on the ground drive
assemblies.
Equipment Damage/Material Loss Risks:
The ground drive contact wheel and chain system will operate
whenever the planter is lowered and in motion. If planting
without fertilizing, the pump must not be allowed to run dry.
Disconnect the chain or remove a sprocket.
Note: When a Type 3 fertilizer system is installed, the
pump is mounted at the source (not on the planter),
usually on a tank cart.
For sprocket settings, refer to the Seed Rate manual.
Figure 68
John Blue Pump
Sprocket and Dial
28416
2
4
3
1
1
2
4
Figure 69
Hypro Pump Sprockets
26319
5
1
2