Ground drive fertilizer pump, Fertilizer manifolds, Manifold selection – Great Plains YP2425F-2470 Operator Manual User Manual
Page 116
112
YP2425 & YP2425F
Great Plains Manufacturing, Inc.
401-406M
2014-07-14
Ground Drive Fertilizer Pump
One or two pump kits integrate with the Type 2 fertilizer
manifold system. They are mounted on the wing tool
bars. Typical starter fertilizer applications require only
one pump. A second pump is necessary at and above 20
gallons per acre.
These pumps are for use with an SML cart or the 400
gallon tank on the PFC2000 cart. Point-row operations
are not supported. Pumps operate whenever the row
units are lowered. See the Seed Rate manual for use.
Fertilizer Manifolds
The YP24 supports either/both of optional “wet” fertilizer
distribution systems for fertilizer application.
The Type 3 boom is separately plumbed for each of the 3
planter sections, and relies on an off-planter pump.
The Type 2 boom has a single inlet, and is optimized for
use with a ground drive pump on each wing. The type 2
boom may also be used with off-planter pumps.
Boom systems are factory-installed. All booms have the
same number of outlets. Unused outlets are capped on
wider row spacings.
An optional ground-drive fertilizer pump is available for
the Type 2 system. The Type 3 system relies on a pump
at the supply tank.
Both systems rely on off-planter tank systems separately
provisioned. The Trailer Hitch Weldment is also required
with either fertilizer system. For operations, see the Seed
Rate manual.
Manifold Selection
Order the (quantity) of parts listed for your configuration.
Option Packages
Part Number
Ground Drive Fertilizer Pump Kit
407-213A
Second Pump Kit
407-218A
28416
26077
Great Plains PFC Systems
Great Plains SML and Aftermarket Systems
Delivery
Systems
PFC2000 only PFC1600 only
PFC1600,
1 saddle tank
SML Cart,
1 tank,
no pumps
Aftermarket
Cart, 1 tank,
1 pump
a
a. Aftermarket equipment must provide its own On/Off and Rate control.
Aftermarket
Cart, 2 tanks,
2 pumps
a
One
(1) PFC2000
b
(1) 407-138A
(1) 401-467A
b. This configuration presumes switching between tanks using the same material.
(1) PFC1600
(1) 407-138A
(1) 401-467A
N/A
(1
c
) 407-213A
(1) 407-215A
(1) 401-467A
c. Order two pumps for extremely high rate Type 2 boom operations.
(1) 407-215A
d
(1) 401-467A
d. If aftermarket cart or pumping system has point-row capability, order (1) 407-138A and (1) 407-215A.
N/A
Two
(1) PFC2000
(1
c
) 407-213A
(1) 407-138A
(1) 407-215A
(1) 401-467A
N/A
(1) PFC1600
(1
c
) 407-213A
(1) 407-138A
(1) 407-215A
(1) 401-467A
N/A
N/A
(2) 407-215A
(1) 401-467A
d