Ultra-cut 400 xt, Group 7 - pilot proportional valve (v3), Group 8 - shield gas proportional valve (v1) – Tweco 400 XT Ultra-Cut Plasma Cutting System With Automated Gas Control User Manual
Page 96
![background image](/manuals/595223/96/background.png)
ULTRA-CUT 400 XT
4-28
OPERATION
Manual 0-5306
Group 5 - Plasma High Proportional Valve (V5)
5-1
Valve open
Check for open connection; Replace valve.
5-2
DPC inlet Supply pressure low Raise plasma inlet pressure; check for DMC valve not open; restriction in gas supply / hoses.
5-3
Outlet pressure too low
Valve full open. Leak in plasma hose to torch; defective control valve (V5); defective pressure
sensor (PS6); DPC Control PCB
5-4
Outlet pressure low
Tracking error Leak in plasma hose to torch; defective control valve (V5); defective pressure sen-
sor (PS6); DPC Control PCB
5-5
Outlet pressure too high.
Valve at minimun setting. Restriction in plasma hose, torch, DPC manifold; defective control
valve (V5); defective pressure sensor (PS6); DPC Control PCB
DPC Status Code Key
Code
Message
Cause/Remedy
Group 6 - Plasma Low Proportional Valve (V4)
6-1
Valve open
Check for open connection; Replace valve.
6-2
DPC inlet Supply pressure
low
Raise plasma inlet pressure; check for DMC valve not open; restriction in gas supply/hoses.
6-3
Outlet pressure too low
Valve full open but pressure still too low. Leak in plasma hose to torch; Defective control valve (V4);
Defective pressure sensor (PS6); DPC Control PCB
6-4
Outlet pressure low
Tracking error. Leak in plasma hose to torch; Defective control valve (V4); Defective pressure sensor
(PS6); DPC Control PCB
6-5
Outlet pressure Too high
Valve at minimum setting but pressure still too high. Restriction in plasma hose to torch; torch or
DPC manifold; Defective control valve (V4); Defective pressure sensor (PS6); DPC Control PCB
6-6
Outlet pressure high
Tracking error. Restriction in plasma hose; torch or DPC manifold; Defective control valve (V4);
Defective pressure sensor (PS6); DPC Control PCB
Group 7 - Pilot Proportional Valve (V3)
7-1
Valve open
Check for open connection; Replace valve.
7-2
DPC inlet Supply pressure
low
Raise plasma inlet pressure; check for DMC valve not open; restriction in gas supply/hoses.
7-3
Outlet pressure too low
Valve full open but pressure still too low. Leak in plasma hose to torch; defective control valve;
defective pressure sensor (PS6); DPC Control PCB
7-4
Outlet pressure low
Tracking error. Leak in plasma hose to torch; defective control valve; defective pressure sensor
(PS6); DPC Control PCB
7-5
Outlet pressure Too high
Valve at minimum setting but pressure still too high. Restriction in plasma hose, torch, DPC mani-
fold; defective control valve; defective pressure sensor (PS6); DPC Control PCB
7-6
Outlet pressure high
Tracking error. Restriction in plasma hose, torch, DPC manifold; defective control valve; defective
pressure sensor (PS6); DPC Control PCB
Group 8 - Shield Gas Proportional Valve (V1)
8-1
Valve open
Check for open connection; Replace valve.
8-2
DPC inlet Supply pressure
low
Raise plasma inlet pressure; check for DMC valve not open; restriction in gas supply/hoses.
8-3
Outlet pressure too low
Valve full open but pressure still too low. Leak in plasma hose to torch; defective control valve;
defective pressure sensor (PS5); DPC Control PCB
8-4
Outlet pressure low
Tracking error. Leak in plasma hose to torch; defective control valve; defective pressure sensor
(PS5); DPC Control PCB
8-5
Outlet pressure Too high
Valve at minimum setting but pressure still too high. Restriction in plasma hose, torch, DPC mani-
fold; defective control valve; defective pressure sensor (PS5); DPC Control PCB
8-6
Outlet pressure high
Tracking error. Restriction in plasma hose, torch, DPC manifold; defective control valve; defective
pressure sensor (PS5); DPC Control PCB