20 install tsc-3000 touch screen control, Install tsc-3000 touch screen control -31, Ultra-cut 400 xt – Tweco 400 XT Ultra-Cut Plasma Cutting System With Automated Gas Control User Manual
Page 53
![background image](/manuals/595223/53/background.png)
ULTRA-CUT 400 XT
Manual 0-5306
INSTALLATION
3-31
Fiber Optic to/from DMC-3000 plugs in here
Art # A-09155
7. Reinstall the Cover Panels making sure the wire harnesses are attached.
3.20 Install TSC-3000 Touch Screen Control
Mounting Dimensions
6.99 in
[177.5 mm]
TSC-3000 Profile
5.58 in
[141.7 mm]
2.35 in
[59.69 mm]
1.11 in
[28.2 mm]
12.45 in
[316.2 mm]
.25 in
[6.35 mm]
11.80 in
[299.7 mm]
10.83 in
[275.0 mm]
TSC-3000 Top
Art # A-09156
Preparation
1. Select a clean, dry location with good ventilation and adequate working space around all components. Review the safety
precautions in the front of this manual to be sure that the location meets all safety requirements. The TSC-3000 mounting
brackets allow for mounting on or under a horizontal surface as well as left or right of a vertical surface. Choose which
ever works best for protection against moving equipment and flying metal/cutting debris etc..
2. Once the unit has been secured to a flat surface, attach Communication cable (“V” which is already attached to the CCM
done in sub section 3.10) and ground cable (“F”) to the rear of the unit.
NOTE
Make sure the CCM CPU jumper is set to 2 Wire (2W) noted earlier in section 3.13 and in the Appendix.