Ultra-cut 400 xt – Tweco 400 XT Ultra-Cut Plasma Cutting System With Automated Gas Control User Manual
Page 82
![background image](/manuals/595223/82/background.png)
ULTRA-CUT 400 XT
4-14
OPERATION
Manual 0-5306
You can change consumables by removing power or using the “Plasma Disable” SW.
If you remove power the system does not remember what gasses were last used so you have to select the process again and
it will do a complete purge including nitrogen buffer even if you do not change gas types.
With “Plasma Disable” the system remembers what was used last and does only the amount of purge necessary possibly
saving time.
11. Use “Plasma Disable”.
a) You may use the Plasma Disable when removing the torch cartridge to change or inspect consumables. Plasma
disable stops coolant pump, shuts off all gas solenoids, removes power from the inverter (power supply) and pilot
circuits, inhibits the arc starter ignition (HF) circuit. It does not remove power from the TSC 3000 or the systems
logic and communications circuits so you do not need to go through as long a power up process after replacing the
consumables.
b) If changing to a process with a different gas type you may want to select it before enabling the plasma otherwise it
will start purging the old process and when you do select the new one it will purge again taking more time.
c) If you are not changing gas type you may want to turn on the Enable first to start the purge while you enter the
process.
12. Shutting off power.
a) If you chose to shut off power for inspecting or changing consumables, or any other purpose, the system does not
remember what you were doing last so you will have to go through the complete sequence from the beginning start-
ing with step 1.
Operational Suggestions
1. Wait four minutes before setting the ON/OFF switch to OFF after operation. This allows the cooling fans to remove
operating heat from the power supply.
2. For maximum parts life, do not operate the pilot arc any longer than necessary.
3. Use care in handling torch leads and protect them from damage.
4. When using water as the shield note the following:
• Use clean drinking quality tap water to help prevent particulate build-up within the system water shield plumbing.
• Particulate contamination and build-up can cause reduced consumable parts life and premature torch failure.
• A cartridge type particulate water filter may help achieve optimum cutting performance.