05 coolant leak trouble-shooting, Coolant leak trouble-shooting -5, Ultra-cut 400 xt – Tweco 400 XT Ultra-Cut Plasma Cutting System With Automated Gas Control User Manual
Page 123

ULTRA-CUT 400 XT
Manual 0-5306
TORCH INFORMATION
7-5
7.05 Coolant Leak Trouble-Shooting
Never operate the system if coolant leaks from the torch. A steady drip indicates that torch parts are damaged or installed im-
properly. Operating the system in this condition can damage the torch head. Refer to the following chart for guidance on coolant
leakage from the torch head.
No
Yes
Yes
Are Parts New
or Used?
Are Parts fully
assembled into
the Torch?
Unsure?
Disassembly fully
and re-assemble
the Torch Properly.
See Installation Manual.
Replace Torch Head
Is the Torch Damaged?
Replace Consumable
Cartridge and Shield Cup.
Torch still leaks?
Remove and Lubricate
all O-rings on Torch Head,
Consumables Cartridge,
and Consumables.
Re-assemble Torch.
Still leaks?
The parts probably are worn out.
See chart for approximate life expectancy.
The torch may be damaged. See page
to determine if head damage has occurred.
Order Coolant
Tube Replacement Kit
Leaking from
Coolant Supply or
Coolant Return?
Yes
Yes
Yes
No
Return
Supply
Used
Order Coolant
Check Valve
Kit 9-4846
New
Torch leaks
Are Torch
Consumable Parts
Installed?
Art # A-09638