Ultra-cut 400 xt – Tweco 400 XT Ultra-Cut Plasma Cutting System With Automated Gas Control User Manual
Page 94

ULTRA-CUT 400 XT
4-26
OPERATION
Manual 0-5306
Group 3 - CCM Communication Port *
3-1
CCM Acknowledge error
Check DMC to CCM fiber optic cable and connections; Dirty or defective fiber-optic;
Replace DMC Control PCB; Replace CCM.
3-2
CCM Bus off error
Check DMC to CCM fiber optic cable and connections; Dirty or defective fiber-optic;
Replace DMC Control PCB; Replace CCM.
3-3
Reserved
No information available; Contact customer service
Group 4 - Gas Controller Status and Protocal Errors
4-1
CCM Connection loss
Loss of communication with either DPC or DMC; check for dirty or defective fiber optic
to either DPC or CCM; See DPC and CCM status codes
4-2
CCM Timeout
Loss of communication with either DPC or DMC, check for dirty or defective fiber-optic
to either DPC or CCM. See DPC and CCM status codes.
4-3
DPC Timeout
Loss of communication with DPC, check for dirty or defective fiber-optic to DPC. See
DPC status code.
4-4
DPC error
Loss of communication with DPC, check for dirty or defective fiber-optic to DPC. See
DPC status code.
4-5
Reserved
No information available; Contact customer service
4-6
Reserved
No information available; Contact customer service
Group 5 - Shorted Solenoid Faults
5-1
Sol 1 – H35 Plasma
Replace solenoid; Shorted wire harness; Defective DMC Control PCB
5-2
Sol 2 – Oxygen Plasma
Replace solenoid; Shorted wire harness; Defective DMC Control PCB
5-3
Sol 3 – Air Plasma
Replace solenoid; Shorted wire harness; Defective DMC Control PCB
5-4
Sol 4 – Nitrogen Plasma
Replace solenoid; Shorted wire harness; Defective DMC Control PCB
5-5
Sol 5 – Aux Plasma
Replace solenoid; Shorted wire harness; Defective DMC Control PCB
5-6
Sol 6 – Oxygen Shield
Replace solenoid; Shorted wire harness; Defective DMC Control PCB
5-7
Sol 7 – Air Shield
Replace solenoid; Shorted wire harness; Defective DMC Control PCB
5-8
Sol 8 – Nitrogen Shield
Replace solenoid; Shorted wire harness; Defective DMC Control PCB
5-9
Sol 9 – H2O Shield
Replace solenoid; Shorted wire harness; Defective DMC Control PCB
5-10
Sol 10 – Oxygen Preflow Replace solenoid; Shorted wire harness; Defective DMC Control PCB
5-11
Sol 11 – Air Preflow
Replace solenoid; Shorted wire harness; Defective DMC Control PCB
5-12
Sol 12 – Nitrogen Preflow Replace solenoid; Shorted wire harness; Defective DMC Control PCB
5-13
Sol 13 – Argon Marking
Replace solenoid; Shorted wire harness; Defective DMC Control PCB
5-14
Sol 14 – Air Marking
Replace solenoid; Shorted wire harness; Defective DMC Control PCB
5-15
Sol 15 – Nitrogen Mark-
ing
Replace solenoid; Shorted wire harness; Defective DMC Control PCB
* Communication faults shown on the DMC can be caused by the device on the other end of the communication line.
Before assuming the DMC is at fault see if either the CCM or the DPC are showing any codes that might indicate they are at
fault instead.