beautypg.com

Rockwell Automation MPAS Integrated Linear Stages User Manual

Page 89

background image

Rockwell Automation Publication MP-UM001D-EN-P - September 2013

89

Interconnect Diagrams

Appendix D

Figure 24 - Wiring Examples for MP-Series Linear Stages and Kinetix 6000 Drives

D

C

B

A

BR+

BR-

F

G

W

V

U

0
1
2
3
4
5
6
7
8
9

10
11
12
13
14
15

SIN+

SIN-

COS+

COS-

D ATA+

D ATA-

+5VDC

ECOM

GREEN

WHT/GREEN

GR AY

WHT/GR AY

BLACK

WHT/BLACK

RED

WHT/RED

3
4

5
6

1
2

9

10

1
2

3
4

5

10

14

6

14

12

+9VDC

TS+

ORANGE

WHT/ORANGE

11
13

7

11

4

3

2

1

6

5

4

3

2

1

Green/ Yellow

Blue

Black

Brown

Black

White

GND

W

V

U

GND

Shield

W

V

U

MBRK -

MBRK +

COM

PWR

DBRK -

DBRK +

BR+

BR-

TS-

COM

BLUE

AM+

AM-

BM+

BM-

IM+

IM-

+5VDC

ECOM

BLUE

WHT/BLUE

GREEN

WHT/GREEN

GR AY

WHT/GR AY

BLACK

WHT/BLACK

RED

WHT/RED

1
2

3
4

5

10

14

6

12

TS-

S1

TS+

ORANGE

WHT/ORANGE

11

S2
S3

COM

YELLOW

WHT/YELLOW

13

8

3
4

5
6

1
2

14
15
16
17
12

11
13

9

10

D

C

B

A

User Supplied
24V DC

MPAS-A/Bxxxx-V05SxA and

MPAS-A/Bxxxx-V20SxA

Ball Screw Stage with

High Resolution Feedback

Thermostat

Three-Phase
Motor Power

Brake

KINETIX 6000

IAM (inverter) or AM

Note 2

Cable Shield

Clamp

Note 1

Motor Power

(MP) Connector

Motor/Resistive
Brake (BC) Connector

Resistive Brake
Connections

Motor Feedback

(MF) Connector

(IAM/AM)

Motor

Feedback

Motor Feedback
(MF) Connector

MPAS-A/Bxxxx-ALMx2C

Direct Drive Stages with

Incremental Feedback

Thermostat

Three-Phase
Motor Power

Motor Feedback

(MF) Connector

(IAM/AM)

Refer to Low Profile Connector

illustration (lower left)

for proper grounding technique.

Exposed shield secured

under clamp

Clamp

Turn clamp over to hold

small cables secure

Clamp screw

Low Profile Connector

(2090-K6CK-D15M shown)

Grounding Technique for

Feedback Cable Shield

Connection to Drive

Motor

Feedback

Refer to Low Profile Connector

illustration (lower left)

for proper grounding technique.

Motor Power Cable

connects to Motor Power (MP)

and Cable Shield Clamp

as shown above

2090-CPWM7DF-16AAxx

(standard)

or 2090-CPBM7DF-16AAxx

(with brake)

Motor Power Cable

Note 3

Use 2090-CPWM7DF-16AFxx

cable for continuous-flex

non-brake applications.

2090-CFBM7DF-CEAAxx (standard) or

2090-CFBM7DF-CEAFxx (continuous-flex)

(flying-lead) Feedback Cable

Note 3,4

2090-XXNFMF-Sxx (standard) or

2090-CFBM7DF-CDAFxx (continuous-flex)

(flying-lead) Feedback Cable

Note 3,4