Chapter 5 - connector data, Linear stage power and feedback connections, Chapter 5 – Rockwell Automation MPAS Integrated Linear Stages User Manual
Page 39: Connector data, Chapter
Rockwell Automation Publication MP-UM001D-EN-P - September 2013
39
Chapter
5
Connector Data
Linear Stage Power and
Feedback Connections
The following tables identify the power and feedback pinouts for circular
connectors for used with standard Allen-Bradley cables.
The direct drive and ball screw linear stages use different encoder types.
Consequently, the feedback connector signals are different for each of these
linear stage types.
Table 3 - Power Connector
Topic
Page
Linear Stage Power and Feedback Connections
Pin
Color
(1)
(1) These are the wire colors for the leads on the direct drive linear stages (catalog number MPAS-xxxxxx-ALMx2C).
Wires for the ball screw linear stages (catalog number MPAS-xxxxxx-V0xxSxA) are not field accessible.
Signal
A
Red
U (A) Phase
B
White
V (B) Phase
C
Black
W (C) Phase
D
Green/Yellow
Ground
F
White
Brake+
(2)
(2) Brake+ and Brake- are available on only the ball screw linear stages having a rotary motor with a brake.
G
Black
ATTENTION: Disconnect input power supply before installing or servicing
stage.
Properly ground the stage as described in both this manual and the drive
manual
A
C
B
D
E
H
L
F
Intercontec P/N BKUA145NN00480200000
Mating Allen-Bradley Power Cable
2090-CPWM7DF-16AAxx (standard) or
2090-CPWM7DF-16AFxx (continuous-flex) or
2090-CPBM7DF-16AAxx (with brake)