Component Replacement
Electrostatic Discharge
Precautions
Follow these ESD precautions:
• Transport the computer and replacement parts in static-safe containers,
such as conductive tubes, bags, or boxes.
• Keep electrostatic-sensitive parts in their containers until they arrive at the
designated static-free work area.
• Cover the designated work area with approved static-dissipating material:
– Use an antistatic wriststrap that is connected to the work surface.
– Use properly grounded tools and equipment.
• Keep the designated work area free of nonconductive materials, such as
plastic assembly aids and foam packing.
• Avoid contact with pins, leads, or circuitry.
• Always hold components with a printed circuit board (PCB) by its edges
and place it with the assembly side down.
Pre-configuration
Follow these steps before you remove the cover or you replace a hardware component.
1. Shut down the computer and all peripherals that are connected to it.
2. Disconnect all cables from power outlets to avoid exposure to high energy
levels.
If necessary, label each cable to expedite reassembly.
3. Disconnect telecommunication cables to avoid exposure to a shock hazard
from ring voltages.
ATTENTION: Electrostatic discharge (ESD) can damage static-sensitive devices
or microcircuitry.
• Disconnect all power before you work on the computer as detailed in
• Observe proper packaging and grounding techniques to help prevent damage.
IMPORTANT
Before you install hardware or perform maintenance procedures that require
access to internal components, we recommend that you first back up all
computer data to avoid loss.
ATTENTION: Make sure to read and understand all installation and removal
procedures before you configure the computer hardware.