Lost passwords - using the installation / key card, Lost passwords – using the installation / key card – Rockwell Automation 5370-CUPK Color CVIM USER-PAK Option User Manual
Page 32
Chapter 4
Getting Started/Using the Security Levels
4 – 10
The USER-PAK option provides a method to effectively override the
password security feature, and enter the setup mode at the
ADMINISTRATOR level. This is accomplished through the use of the
Installation / Key card. This “key” method of entry is especially important if
the password for the administrator level is lost or is otherwise unavailable.
To enter the setup mode using the Installation / Key card, complete these
steps:
•
If the Color CVIM module is in setup mode, go to run mode.
•
Insert the Installation / Key card into the Archive Memory slot on the
Color CVIM module.
•
Pick the
Setup
box on the runtime menu to display the password entry
keyboard (Note: If
Security
has been set to
OFF
, hold the tip of the light
pen down upon the Setup box until the keyboard appears. If you are using
a mouse, place the cursor over the
Setup
box, and hold the left mouse
button until the keyboard appears).
•
Enter the 3-character default password
A-B
on the password entry
keyboard, and pick the
Ret
key.
Changing passwords with the key card inserted: After entering the setup
mode at the ADMINISTRATOR level, it is possible to change the password
for the ADMINISTRATOR level – or any other level. While the Installation
/ Key card is inserted, the default password
A-B
can be used as the “old
password” when changing passwords (see “Changing Passwords” earlier in
this chapter).
Lost Passwords – Using
the Installation / Key Card