Replace the Ultra3000 (230V) Power Specifications table on page A-3
with the one shown below. The new table includes an updated value
in the bus capacitance field for 2098-DSD-030 drives.

Ultra3000 Drive (230V) Power Specifications

2098-DSD-030x-xx, 2098-DSD-075x-xx, and 2098-DSD-150x-xx

Specification

Description

2098-DSD-030

2098-DSD-075

2098-DSD-150

AC input voltage

(1)

100...240V rms
Single-phase

100...240V rms
Three-phase

AC input frequency

47...63 Hz

Main ac input current

(2) (3)

Nom (rms)
230V ac (0-pk) Max inrush

28 A
50 A

30 A
50 A

46 A
68 A

Auxiliary ac Input current

115V ac (rms) Nom
230V ac (rms) Nom
115V ac (0-pk) Max inrush

(4)

230V ac (0-pk) Max inrush

(4)

1.0 A
0.5 A
47 A
95 A

1.0 A
0.5 A
47 A
95 A

1.0 A
0.5 A
47 A
95 A

Continuous output current (0-pk)

15 A

35 A

65 A

Intermittent output current (0-pk)

30 A

75 A

150 A

Bus capacitance

2820 μF

4290 μF

7520 μF

Internal shunt resistance

35

Ω

16.5

Ω

9.1

Ω

Shunt on

420V dc

420V dc

420V dc

Shunt off

402V dc

402V dc

402V dc

Bus overvoltage

452V dc

452V dc

452V dc

Internal shunt

Continuous power
Peak power

50 W
4.5 kW

50 W
10 kW

180 W
18 kW

External shunt

Resistance
Continuous power
Peak power

30

Ω (-0/+5%)

2.4 kW
6 kW

16.5

Ω (-0/+5%)

4 kW
10 kW

9

Ω (-0/+5%)

8 kW
19 kW

Energy absorption capability

115V ac input
230V ac input

211 J
117 J

381 J
211 J

669 J
370 J

Continuous power output

115V ac input
230V ac input

1.5 kW
3 kW

3.75 kW
7.5 kW

7.5 kW
15 kW

(1)

Specification is for nominal voltage. The absolute limits are ±10%, or 88...265V rms.

(2)

The 2098-DSD-030x-xx, -075x-xx, and -150x-xx (230V) drives are limited to one contactor cycles per two minutes.

(3)

Power initialization requires a short period of inrush current. Dual-element time delay (slow blow) fuses are recommended.

(4)

400

μs half wave sine.

ATTENTION

The inrush current-limiting circuitry is limited in the number of
power cycles it can withstand within a set period of time. If you
exceed these limitations, the circuitry will be damaged.