beautypg.com

Digital inputs, Using an external +5v logic supply – Rockwell Automation 2090 Ultra3000 Installation Manual User Manual

Page 70

background image

Publication 2098-IN003E-EN-P — April 2004

2-28

Ultra3000 Connector Data

Using an External +5V Logic Supply

When using an external +5V dc power supply with your Ultra3000
(2098-DSD-005, -010, and -020), the +5V dc must not be grounded
inside the supply, since it will be referenced to the drive common.
External +5V dc power supply connections should be made to CN1-2
and CN1-3.

The following table provides a description of the requirements for an
external +5V dc power supply used to power the logic.

Digital Inputs

There are eight opto-isolated digital inputs. All digital inputs (SERCOS
and non-SERCOS) have the same configuration, as shown in the figure
below.

Figure 2.13
Digital Input Circuit

IMPORTANT

Using the drive-mounted breakout board with 24V to
5V auxiliary power converter is preferred to using an
external +5V dc power supply.

Parameter

Description

Minimum

Maximum

Voltage

Voltage tolerance of the external logic supply.

5.1V

5.25V

Current

Current output capability of the external +5V dc power
supply.

1.5A

2.7k

Ω

+5V

INPUTS

10k

Ω

1k

Ω

IOCOM

DGND

IOCOM

TLP121

Ultra3000 Drive