beautypg.com

Attention – Rockwell Automation 2090 Ultra3000 Installation Manual User Manual

Page 177

background image

Publication 2098-IN003E-EN-P — April 2004

Interconnect Diagrams

B-23

Ultra3000 to IMC-S
Compact Cable and
Interconnect Diagram

This section provides information to assist you in wiring the

IMC-S/23x-xx Compact Controller when connecting the 4100-CCS15F
feedback cable and 4100-CCA15F I/O cable to your Ultra3000.

Figure B.24
Ultra3000 to IMC-S/23x-xx
Compact Controller Configuration

1

The preferred method for supplying the auxiliary +5V is by using the 12- or 44-pin drive mounted breakout board
with 24V to 5V auxiliary power converter (catalog number 2090-U3CBB-DM12 or -DM44). Auxiliary +5V power is
required to maintain encoder position with an external position controller during a controlled stop condition.

2

Drive Enable and Fault Reset are configured in Ultraware software.

3

Relay Output (CN1, pins 43 and 44) must be configured as Ready in Ultraware software.

A+

A-

B+

B-

Z+

Z-

+ENC (5V)

ENC COM

BLUE

BLACK

WHITE

BLACK

GREEN

BLACK

16

17

18

19

20

21

3

2

BLACK

1

7

4

10

5

11

6

12

3

9

8

2

IMC S Class Compact Controller

IMC-S/23

x-xx

Axis Servo and Feedback Connector

(located on bottom of controller)

Ultra3000

44-pin Breakout Board

(without SERCOS interface)

CN1 Connector

4100-CCS15F Feedback Cable

N/C

CMD+

CMD-

25

26

A+

A-

B+

B-

Z+

Z-

ENC PWR

ENC COM

REF+

REF-

SHIELD

STROBE

+24V I/O PWR

+24V I/O PWR

24V I/O COM

24V I/O COM

DIGITAL INPUT 1

DIGITAL OUT 1

DIGITAL INPUT 2

BLACK

BLUE

RED

WHITE

GREEN

BROWN

30

29

28

27

31

39

32

ORANGE

PURPLE

4

1

2

3

9

5

6

8

7

+ 24V

HOME

POS OT

NEG OT

24V COM

DRIVE EN

DRIVE EN

DRIVE FLT-

DRIVE FLT+

YELLOW

Fault Reset P.B.

2

2

RELAY OUT+

RELAY OUT-

43

44

Axis I/O Connector

(located on top of controller)

4100-CCA15F I/O Cable

3

3

1

24V AC/DC

or

120V AC,
50/60 HZ

START*

CR1*

M1*

CR1*

CR1*

STOP*

Refer to Attention statement below

ATTENTION

!

Implementation of safety circuits and risk assessment
is the responsibility of the machine builder. Please
reference international standards EN1050 and EN954
estimation and safety performance categories. For
more information refer to Understanding the
Machinery Directive
(publication SHB-900).

This manual is related to the following products: