A065 [Sel. uscita anlg]
0/23
1
0
A066 [Uscita anlg alta]
0/800%
1%
100%
A067 [Tempo accel. 2]
0,0/600,0 sec
0,1 sec
20,0 sec
A068 [Tempo decel. 2]
0,1/600,0 sec
0,1 sec
20,0 sec
A069 [Freq interna]
0,0/400,0 Hz
0,1 Hz
0,0 Hz (per gli
inverter IP66,
NEMA/UL
Type 4X)
60,0 Hz (per
inverter IP20)
A070
A071
A072
A073
A074
A075
A076
A077
[Freq. predef. 0]
(1)
[Freq. predef. 1]
[Freq. predef. 2]
[Freq. predef. 3]
[Freq. predef. 4]
[Freq. predef. 5]
[Freq. predef. 6]
[Freq. predef. 7]
0,0/400,0 Hz
0,1 Hz
0,0 Hz
5,0 Hz
10,0 Hz
20,0 Hz
30,0 Hz
40,0 Hz
50,0 Hz
60,0 Hz
(1)
Per attivare [Freq predef 0] impostare il parametro P038 [Rif velocità] sull’opzione 4.
A078 [Frequenza jog]
0,0/[Frequenza max]
0,1 Hz
10,0 Hz
A079 [Accel/decel/ jog]
0,1/600,0 sec
0,1 sec
10,0 sec
A080 [Tempo freno CC]
0,0/99,9 sec
0,1 sec
0,0 sec
Impostando 99,9 sec. = Continuo
A081 [Liv freno CC]
0,0/(Ampere inverter
×
1,8)
0,1 Amp
Ampere
×
0,05
A082 [Sel resis freno d.]
0/99
0 = “Disabilitato”
1 = “Res RA norm”
2 = “No protez.”
3-99 = % ciclo di carico
0
A083 [% Curva S]
0/100%
1%
0%
(disabilitato)
N.
Parametro
Min/Max
Display/Opzioni
Valore
predefinito
Opzione
Gamma uscita
Valore di uscita
minimo
Valore di uscita massimo
[Uscita anlg alta]
Posizione
microinterruttore
0 “FreqUsc 0-10”
0-10 V
0 V = 0 Hz
P035 [Frequenza max]
0-10 V
1 “CorrUsc 0-10”
0-10 V
0 V = 0 ampere
200% FLA nominale inverter
0-10 V
2 “VoltUsc 0-10”
0-10 V
0 V = 0 Volt
120% volt uscita nominale inverter
0-10 V
3 “PotUsc 0-10”
0-10 V
0 V = 0 kW
200% potenza nominale inverter
0-10 V
4 “DatiPr 0-10”
0-10 V
0 V = 0000
65535 (FFFF esadecimali)
0-10 V
5 “FreqUsc 0-20”
0-20 mA
0 mA = 0 Hz
P035 [Frequenza max]
0-20 mA
6 “CorrUsc 0-20”
0-20 mA
0 mA = 0 ampere
200% FLA nominale inverter
0-20 mA
7 “VoltUsc 0-20”
0-20 mA
0 mA = 0 Volt
120% volt uscita nominale inverter
0-20 mA
8 “PotUsc 0-20”
0-20 mA
0 mA = 0 kW
200% potenza nominale inverter
0-20 mA
9 “DatiPr 0-20”
0-20 mA
0 mA = 0000
65535 (FFFF esadecimali)
0-20 mA
10 “FreqUsc 4-20”
4-20 mA
4 mA = 0 Hz
P035 [Frequenza max]
0-20 mA
11 “CorrUsc 4-20”
4-20 mA
4 mA = 0 ampere
200% FLA nominale inverter
0-20 mA
12 “VoltUsc 4-20”
4-20 mA
4 mA = 0 Volt
120% volt uscita nominale inverter
0-20 mA
13 “PotUsc 4-20”
4-20 mA
4 mA = 0 kW
200% potenza nominale inverter
0-20 mA
14 “DatiPr 4-20”
4-20 mA
4 mA = 0000
65535 (FFFF esadecimali)
0-20 mA
15 “CoppUsc 0-10” 0-10 V
0 V = 0 ampere
200% FLA nominale inverter
0-10 V
16 “CoppUsc 0-20” 0-20 mA
0 mA = 0 ampere
200% FLA nominale inverter
0-20 mA
17 “CoppUsc 4-20” 4-20 mA
4 mA = 0 ampere
200% FLA nominale inverter
0-20 mA
18 “Prest 0-10”
0-10 V
0 V = 0%
100,0% impostazione setpoint
0-10 V
19 “Prest 0-20”
0-20 mA
0 mA = 0%
100,0% impostazione setpoint
0-20 mA
20 “Prest 4-20”
4-20 mA
4 mA = 0%
100,0% impostazione setpoint
0-20 mA
21 “FreqMin 0-10”
0-10 V
0V = freq min.
P035 [Frequenza max]
0-10 V
22 “FreqMin 0-20”
0-20 mA
0 mA = freq min.
P035 [Frequenza max]
0-20 mA
23 “FreqMin 4-20”
4-20 mA
4 mA = freq min.
P035 [Frequenza max]
0-20 mA
Stato ingresso
di ingr dig 1
(morsetto I/O 05)
Stato ingresso
di ingr dig 2
(morsetto I/O 06)
Stato ingresso
di ingr dig 3
(morsetto I/O 07)
Sorgente della
frequenza
Parametro
di accelerazione/
decelerazione usato (2)
0
0
0
[Freq. predef. 0]
[Tempo accel. 1] / [Tempo decel. 1]
1
0
0
[Freq. predef. 1]
[Tempo accel. 1] / [Tempo decel. 1]
0
1
0
[Freq. predef. 2]
[Tempo accel. 2] / [Tempo decel. 2]
1
1
0
[Freq. predef. 3]
[Tempo accel. 2] / [Tempo decel. 2]
0
0
1
[Freq. predef. 4]
[Tempo accel. 1] / [Tempo decel. 1]
1
0
1
[Freq. predef. 5]
[Tempo accel. 1] / [Tempo decel. 1]
0
1
1
[Freq. predef. 6]
[Tempo accel. 2] / [Tempo decel. 2]
1
1
1
[Freq. predef. 7]
[Tempo accel. 2] / [Tempo decel. 2]
(2) Quando un ingresso digitale viene impostato su “Accel. 2 e decel. 2” e l’ingresso è attivo, quell’ingresso sovrascrive le
impostazioni contenute in questa tabella.
Per ulteriori informazioni sui parametri, consultare il manuale dell’utente di PowerFlex 40.