Lenze TCF Series User Manual
Page 12
MODEL
NUMBER
(NOTE 1)
FOR MOTORS
RATED
INPUT (50-60 Hz)
OUTPUT
HEAT LOSS
(WATTS)
(NOTE 5)
INPUT
PHASE
CURRENT
(AMPS)
POWER
(kVA)
CURRENT
(AMPS)
HP
kW
TF400 SERIES (NOTE 3)
400 / 480 Vac
0 - 400 / 460 Vac
TF405
0 .5
0 .37
3
1 .6 / 1 .4
1 .1
1 .3 / 1 .1
26
TF410
1
0 .75
3
2 .9 / 2 .5
2 .1
2 .4 / 2 .1
40
TF415
1 .5
1 .1
3
4 .0 / 3 .6
3 .0
3 .4 / 3 .0
56
TF420
2
1 .5
3
4 .6 / 4 .0
3 .3
3 .9 / 3 .4
67
TF430
3
2 .2
3
6 .2 / 5 .4
4 .5
5 .5 / 4 .8
100
TF450
5
4 .0
3
10 .6 / 8 .8
7 .1
9 .4 / 7 .8
168
TF475
7 .5
5 .5
3
14 .2 / 12 .4
10 .3
12 .6 / 11 .0
254
TF4100
10
7 .5
3
18 .1 / 15 .8
13 .1
16 .1 / 14 .0
310
TF500 SERIES (NOTE 4)
480 / 590 Vac
0 - 460 / 575 Vac
TF510
1
0 .75
3
2 .2 / 2 .0
1 .9 / 2 .0
1 .9 / 1 .7
40
TF520
2
1 .5
3
4 .0 / 3 .5
3 .3 / 3 .6
3 .4 / 3 .0
67
TF530
3
2 .2
3
4 .7 / 4 .7
3 .9 / 4 .8
4 .2 / 4 .2
100
TF550
5
3 .7
3
7 .4 / 7 .4
6 .1 / 7 .5
6 .6 / 6 .6
168
TF575
7 .5
5 .5
3
11 .2 / 11 .2
9 .3 / 11 .4
9 .9 / 9 .9
254
TF5100
10
7 .5
3
13 .7 / 13 .7
11 .4 / 14 .0
12 .2 / 12 .2
310
NOTE 1: Refer to Section 3 for model number breakdown .
NOTE 3: The higher current ratings are for 400 Vac input and the lower current ratings are for 480 Vac input .
NOTE 4: The higher current ratings are for 480 Vac input and the lower current ratings are for 590 Vac input .
NOTE 5: Values are worst-case (not typical) for 4kHz carrier frequency at full speed and full load
8