Troubleshooting and fault elimination – Lenze E82EV 8200 User Manual
Page 161

Troubleshooting and fault elimination
Fault elimination
Fault messages
l
161
EDK82EV113 DE/EN/FR 11.0
Remedy
Cause
Fault
PC
1)
Keypad
OC5
a
15
Controller overload
during steady−state
operation
Frequent and too long overload
periods
Check drive dimensioning
OC6
a
16
Motor overload
(I
2
x t overload)
Motor is thermally overloaded by
e.g.
l
impermissible continuous
current
l
Check drive dimensioning
l
frequent or too long
acceleration processes
l
Check setting of C0120
OH
a
50
Heatsink
temperature > +85
°C
Ambient temperature is too high
Allow controller to cool and provide
for better ventilation
OH
e
−
Heatsink
temperature > +80
°C
Heatsink is very dirty
Clean heatsink
OH
e
−
Heatsink
temperature > +80
°C
Impermissible high currents or
frequent and too long
acceleration processes
l
Check drive dimensioning
l
Check load, replace
rough−running, defective
bearings, if necessary
OH3
a
53
PTC monitoring
(TRIP)
(display when
C0119 = 1 or 4)
Motor too hot due to
impermissible high currents or
frequent and too long
acceleration processes
Check drive dimensioning
No PTC connected
Connect PTC or switch off monitoring
OH4
a
54
Controller
overtemperature
Controller is too hot inside
l
Reduce controller load
l
Improve cooling
l
Check fan in the controller
OH51
203
PTC monitoring
(display when
C0119 = 2 or 5)
Motor too hot due to
impermissible high currents or
frequent and too long
acceleration processes
Check drive dimensioning
No PTC connected
Connect PTC or switch off monitoring