Commissioning – Lenze E82EV 8200 User Manual
Page 147

Commissioning
Important codes for quick commissioning
l
147
EDK82EV113 DE/EN/FR 11.0
Code
Possible settings
IMPORTANT
No.
Name
Lenze
Selection
C0002*
s
uSEr
Parameter set
management
0
0
Ready
PAR1 ... PAR4:
l
Parameter sets of the controller
l
PAR1 ... PAR4 also contain the
parameters for the function
modules standard I/O,
application I/O, AS interface,
system bus (CAN)
FPAR1:
l
Module−specific parameter set of
the fieldbus function modules
INTERBUS, PROFIBUS−DP,
LECOM−B, DeviceNet/CANopen
l
FPAR1 is saved in the function
module
Restoring the
delivery status
1
Lenze setting
ð PAR1
Restore the delivery status in the
parameter set selected
2
Lenze setting
ð PAR2
3
Lenze setting
ð PAR3
4
Lenze setting
ð PAR4
31
Lenze setting
ð FPAR1
Restore the delivery status in the
fieldbus function module
61
Lenze setting
ð PAR1 + FPAR1
Restore the delivery status in the
selected parameter set of the
controller and in the fieldbus function
module
62
Lenze setting
ð PAR2 + FPAR1
63
Lenze setting
ð PAR3 + FPAR1
64
Lenze setting
ð PAR4 + FPAR1
C0002*
s
uSEr
(Cont.)
Transferring
parameter sets
with the keypad
By means of the keypad you can
transfer the parameter sets to other
controllers.
During the transmission the access to
the parameters via other channels is
inhibited!
Keypad
ð controller
Overwrite all available parameter
sets (PAR1 ... PAR4, if required FPAR1)
with the corresponding data of the
keypad
70
with function module application I/O,
INTERBUS, PROFIBUS−DP, LECOM−B,
DeviceNet, CANopen
10
with all other function modules