Technical data – Lenze E82EV 8200 User Manual
Page 102
Technical data
General data and operating conditions
l
102
EDK82EV113 DE/EN/FR 11.0
Ambient conditions
DC mains connection
Max. mains voltage range
450 V − 0 % ... 740 V + 0 %
E82xV251K2... and E82xV371K2...
not possible
E82xV551K2... to E82xV752K2...
140 V − 0 % ... 370 V + 0 %
E82xV551K4... to E82xV903K4...
450 V − 0 % ... 775 V + 0 %
Operation at rated power
450 V − 0 % ... 625 V + 0 %
Operation at an increased rated
power
Operating conditions
The DC voltage must be symmetrical to PE.
The controller will be destroyed if the +U
G
conductor or −U
G
conductor is earthed.
Motor connection
Length of the motor cable
< 50 m
shielded
< 100 m
unshielded
For rated mains voltage and switching frequency
£ 8 kHz
without additional output filters.
For compliance with EMC regulations, the permissible cable
length may be different.
Mechanical
Vibration resistance
(9.81 m/s
2
= 1 g)
Germanischer Lloyd
5 ... 13.2 Hz
Amplitude ±1 mm 13.2 ... 100 Hz:
acceleration resistant up to 0.7 g
IEC/EN 60068−2−6
10 ... 57 Hz
Amplitude 0.075 mm 57 ... 150 Hz:
acceleration resistant up to 1 g
Mounting conditions
Mounting place
In the control cabinet
Mounting position
Vertical
Dimensions,
free spaces
^
Chapter "Mechanical installation"
Weights
^
Chapter "Technical data", "Operation at rated power" or
"Operation at increased rated power"