C13848 | last conflicted mac id, C13849 | last conflicted ip address, C13850 | all words to scanner – Lenze E84Dxxxx User Manual
Page 96: C13850, 13 parameter reference
13
Parameter reference
13.1
Parameters relevant for communication
96
Lenze · Decentralised frequency inverter 8400 protec (EtherNet/IP™ option) · Communication Manual · DMS 3.0 EN · 07/2014 · TD17
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C13848
C13849
C13850
Parameter | Name:
C13848 | Last Conflicted MAC ID
Data type: OCTET_STRING
Index: 10727
d
= 29E7
h
Display of the MAC address of the EtherNet/IP node with the last address conflict (ACD).
The data of the last conflict will only be saved in this code if ACD is active at the moment when the conflict occurs
(
= 1).
(Instance attribute 11 (RemoteMAC) in the
TCP/IP Interface Object (245 / 0xF5) ( 124)
)
Read access Write access CINH PLC STOP No transfer PDO_MAP_RX PDO_MAP_TX COM MOT
Parameter | Name:
C13849 | Last Conflicted IP Address
Data type: UNSIGNED_8
Index: 10726
d
= 29E6
h
Display of the MAC address of the EtherNet/IP node with the last address conflict (ACD).
The data of the last conflict will only be saved in this code if ACD is active at the moment when the conflict occurs
(
= 1).
Display range
(min. value | unit | max. value)
0
255
Subcodes
Info
C13849/1
Last conflicted IP address (most significant byte)
C13849/2
Last conflicted IP address
C13849/3
Last conflicted IP address
C13849/4
Last conflicted IP address (least significant byte)
Read access Write access CINH PLC STOP No transfer PDO_MAP_RX PDO_MAP_TX COM MOT
Parameter | Name:
C13850 | All words to scanner
Data type: INTEGER_16
Index: 10725
d
= 29E5
h
Indication of the I/O data words that are transferred from the Inverter Drive 8400 protec (adapter) to the scanner.
In the subcodes, all I/O data words transferred to the scanner are displayed. However, only the configured I/O data
words are valid.
Display range
(min. value | unit | max. value)
-32768
32767
Subcodes
Info
C13850/1
...
C13850/16
Read access Write access CINH PLC STOP No transfer PDO_MAP_RX PDO_MAP_TX COM MOT