12
Error messages
12.4
Mapping of Lenze device errors to DRIVECOM errors
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
xx.0123.00201
SD11: Speed limit - feedback system 67
0x7300
0x7300
Sensor
xx.0123.00205
SD3: Open circuit - feedback system
0x7300
0x7301
Tacho defective
xx.0125.00001
An01: AIN1_I < 4 mA
0xF000
0xF000
Additional functions
xx.0125.00002
An02: AIN2_I < 4 mA
0xF000
0xF000
Additional functions
xx.0125.00011
Io11: DigOut level
0xF000
0xF000
Additional functions
xx.0127.00002
CE04: MCI communication error
0x7000
0x7500
Communication
xx.0127.00003
Smr1: Module internal watchdog or trap
0x6100
0x6010
Software reset (watchdog)
xx.0127.00004
Smr2: Module Offline - no status or PDOs
0x7000
0x7500
Communication
xx.0127.00005
Smr3: Module timeout - one or more of PDOs
timeout
0x7000
0x7500
Communication
xx.0127.00006
Smr4: SDO access failure
0x6100
0x6100
Internal software
xx.0127.00015
CE0F: MCI control word
0xF000
0xF000
Additional functions
xx.0131.00000
CE4: CAN Bus Off
0x8000
0x8000
Monitoring
xx.0131.00006
CA06: CAN CRC error
0x8000
0x8000
Monitoring
xx.0131.00007
CA07: CAN Bus Warn
0x8000
0x8000
Monitoring
xx.0131.00008
CA08: CAN Bus Stopped
0x8000
0x8000
Monitoring
xx.0131.00011
CA0b: CAN Bus Live Time
0x8130
0x8000
Monitoring
xx.0131.00015
CA0F: CAN control word
0xF000
0x8000
Monitoring
xx.0135.00001
CE1: CAN RPDO1
0x8100
0x8100
Communication
xx.0135.00002
CE2: CAN RPDO2
0x8100
0x8100
Communication
xx.0135.00003
CE3: CAN RPDO3
0x8100
0x8100
Communication
xx.0135.00004
CP04: CAN RPDO4
0x8100
0x8100
Communication
xx.0140.00013
MCI1: Module missing/incompatible
0x7000
0x7000
Additional Modules
xx.0144.00001
PS01: No memory module
0x6300
0x6300
Date Set
xx.0144.00002
PS02: Par. set invalid
0x6300
0x6300
Date Set
xx.0144.00003
PS03: Par. set device invalid
0x6300
0x6300
Date Set
xx.0144.00004
PS04: Par. set device incompatible
0x6300
0x6300
Date Set
xx.0144.00007
PS07: Par. mem. module invalid
0x6300
0x6300
Date Set
xx.0144.00008
PS08: Par. device invalid
0x6300
0x6300
Date Set
xx.0144.00009
PS09: Par. format invalid
0x6300
0x6300
Date Set
xx.0144.00010
PS10: Memory module link invalid
0x5000
0x5000
Device Hardware
xx.0144.00031
PS31: Ident. error
0x6300
0x6300
Date Set
xx.0145.00001
dF01: Internal error 01
0x6100
0x6100
Internal software
xx.0145.00002
dF02: Internal error 02
0x6100
0x6100
Internal software
xx.0145.00003
dF03: Internal error 03
0x6100
0x6100
Internal software
xx.0145.00004
dF04: Internal error 04
0x6100
0x6100
Internal software
xx.0145.00005
dF05: Internal error 05
0x6100
0x6100
Internal software
xx.0145.00006
dF06: Internal error 06
0x6100
0x6100
Internal software
xx.0145.00007
dF07: Internal error 07
0x6100
0x6100
Internal software
xx.0145.00008
dF08: Internal error 08
0x6100
0x6100
Internal software
xx.0145.00009
dF09: Internal error 09
0x6100
0x6100
Internal software
xx.0145.00010
dF10: Internal error 10
0x6100
0x6100
Internal software
xx.0145.00014
dF14: SW-HW invalid
0x5530
0x6000
Device software
xx.0145.00024
dF18: BU RCOM error
0x6100
0x6100
Internal software
xx.0145.00025
dF25: CU RCOM error
0x6100
0x6100
Internal software
xx.0145.00033
dF21: BU watchdog
0x6100
0x6010
Software reset (watchdog)
xx.0145.00034
dF22: CU Watchdog
0x6100
0x6010
Software reset (watchdog)
xx.0145.00035
dF10: AutoTrip reset
0xF000
0xF000
Additional functions
xx.0145.00050
dF50: Retain error
0x6100
0x6100
Internal software
xx.0145.00051
dF51: CuCcr error
0x6100
0x6100
Internal software
Lenze error
CAN
DRIVECOM error
Error number
[32 bits]
Error message
Emergency
Error Code
Error number
[hex]
Error message