8i/o data transfer (implicit messages) – Lenze E84Dxxxx User Manual
Page 55
Lenze · Decentralised frequency inverter 8400 protec (EtherNet/IP™ option) · Communication Manual · DMS 3.0 EN · 07/2014 · TD17
55
8
I/O data transfer (implicit messages)
8.5
I/O configuration with »RSLogix 5000« version 19 or lower
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
5. Go to the "New Module" dialog window and define the properties of the newly added
device .
The terms "input" and "output" refer to the point of view of the scanner:
• Assembly input objects (input) are sent from the adapter to the scanner.
• Assembly output objects (output) are sent from the scanner to the adapter.
Settings for Lenze technology applications or user-definable parameter sets:
If a Lenze technology application or an individual parameter set is used in the inverter, the
assembly object instances
"Input = 111" and
"Output = 110" can be used to
exchange up to 16 user-definable words (INT) via ports MCI_IN and MCI_OUT.
Go to
"Configuration" and enter the Assembly instance "130" and the Size "0".