13 parameter reference, 1 parameters relevant for communication, C13000 | ip address – Lenze E84Dxxxx User Manual
Page 88: C13001 | subnetwork mask, Parameter reference, C13000, C13001
13
Parameter reference
13.1
Parameters relevant for communication
88
Lenze · Decentralised frequency inverter 8400 protec (EtherNet/IP™ option) · Communication Manual · DMS 3.0 EN · 07/2014 · TD17
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
13
Parameter reference
This chapter supplements the parameter list and the table of attributes in the reference manual and
the »Engineer« online help for the Inverter Drives 8400 protec by the EtherNet/IP parameters.
13.1
Parameters relevant for communication
This chapter lists the EtherNet/IP parameters in numerically ascending order.
C13000
C13001
Reference manual / »Engineer« online help for Inverter Drives 8400 protec
Here you will find general information on parameters.
Parameter | Name:
C13000 | IP Address
Data type: UNSIGNED_8
Index: 11575
d
= 2D37
h
Setting of the IP address
Setting the IP configuration of the Inverter Drive 8400 protec ( 28)
Setting range
(min. value | unit | max. value)
0
255
Subcodes
Lenze setting
Info
C13000/1
192
IP address (most significant byte)
C13000/2
168
IP address
C13000/3
124
IP address
C13000/4
16
IP address (least significant byte)
Read access Write access CINH PLC STOP No transfer PDO_MAP_RX PDO_MAP_TX COM MOT
Parameter | Name:
C13001 | Subnetwork Mask
Data type: UNSIGNED_8
Index: 11574
d
= 2D36
h
Setting of the subnet mask
Setting the IP configuration of the Inverter Drive 8400 protec ( 28)
Setting range
(min. value | unit | max. value)
0
255
Subcodes
Lenze setting
Info
C13001/1
255
Subnet mask (most significant byte)
C13001/2
255
Subnet mask
C13001/3
255
Subnet mask
C13001/4
0
Subnet mask (least significant byte)