Setting the IP configuration of the Inverter Drive 8400 protec
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
6.3.2
Setting via codes in the »Engineer«
You can also set the IP parameters manually in the »Engineer« under the Settings tab. The values
will be transferred to the corresponding codes.
How to activate changed settings in the »Engineer«:
1. Execute device command C00002 = "11: Save all parameter sets".
The current IP configuration is stored in the memory module of the inverter.
2. Carry out a "type 0 reset" to the
of the bus node or 8400
switch the voltage supply of the Inverter Drive 8400 protec off and then on again.
Settings
Description
IP Config Control
Selection (
) of how the IP configuration is to be made:
• 0: The IP configuration currently stored in the Inverter Drive 8400 protec
is used.
• 1: The IP configuration is assigned by a BOOTP server using the BOOTP.
• 2: The IP configuration is assigned by a DHCP server using the DHCP.
IP Address
Setting of the IP address (
)
Subnet Mask
Setting of the subnet mask (
Gateway Address
Setting of the gateway address (
)
Multicast IP Start Address
Setting of the Multicast IP start address (
Setting the multicast configuration ( 34)
Multicast Config TTL Value
Setting of the multicast TTL value (