4 lenze class (110 / 0x6e), Lenze class (110 / 0x6e) ( 142), 14 implemented cip™ objects – Lenze E84Dxxxx User Manual
Page 142
14
Implemented CIP™ objects
14.4
Lenze objects
142
Lenze · Decentralised frequency inverter 8400 protec (EtherNet/IP™ option) · Communication Manual · DMS 3.0 EN · 07/2014 · TD17
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
14.4.4
Lenze Class (110 / 0x6E)
The "Lenze Class (110 / 0x6E)" enables read or write access to Lenze codes.
The Lenze code must be specified as an "instance" (corresponding code no. 1 ... 65535) and its
subcodes must be specified as "attributes".
Class attributes
Instance attributes
Supported service codes
Note!
• If the corresponding Lenze code does not have a subcode, the value '0' must be
entered in the attribute. If '0' is not supported as attribute value by the engineering
tool used, the value '1' must be entered.
• A display code cannot be configured using "Set_Attribute_Single".
Attribute
ID
Service
Name
Data type
Value
1
Get
Revision
UINT
2 (0x0002)
2
Get
Max. Instance
UINT
1 (0x0001)
Attribute
ID
Service
Name
Data type
Value
0 ... 255
Get / Set Lenze Subcode number
Data type of
the subcode
Value of the subcode
Service code
Name
Description
0x0E
Get_Attribute_Single
Outputs the value of a certain attribute.
0x10
Set_Attribute_Single
Changes the value of a certain attribute.