_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
Parameter
Parameter
Name
Info/Lenze setting
Moto
r potentiom
eter
C00806
Use of motor potentiometer
0 The motor potentiometer is not used.
• The analog value applied to the nIn_a
input is looped through without any
changes to the nOut_a output.
1 The motor potentiometer is used.
• The analog value applied at the nIn_a
input is led via the motor
potentiometer and provided at the
nOut_a output.
C00800
L_MPot_1: Upper limit
100.00 %
C00801
L_MPot_1: Lower limit
-100.00 %
C00802
L_MPot_1: Acceleration time
10.0 s
C00803
L_MPot_1: Deceleration time
10.0 s
C00804
L_MPot_1: Inactive fct.
Behaviour of the motor potentiometer function when
being deactivated via the bInAct input:
0 Keep output value
1 Deceleration via ramp to 0
2 Deceleration via ramp to the lower limit
(C00801)
3 Step change to 0
4 Jump to lower limit (C00800)
5 Acceleration via ramp to upper limit
(C00800)
C00805
L_MPot_1: Init fct.
Behaviour of the motor potentiometer function when
the device is switched on:
0 Load last value
1 Load lower limit
2 Load 0