C00114, C00118, C00434/1 – Lenze E84AVSCx 8400 StateLine C User Manual
Page 40: C00435/1, 6commissioning

6
Commissioning
6.3
Adapting the most important parameters to the drive task
40
Lenze · 8400 StateLine · Operating instructions · from Firmware V06.00 · DMS 1.2 EN · 12/2012 · TD05
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C00114
C00118
C00434/1
C00435/1
Digital inputs (DIx): Polarity
The polarity of each digital input of the device can be inverted via this bit field.
Setting range
(min. hex value | max. hex value)
Lenze setting
0x0000
0xFFFF 0x0000
Decimal: 0
Binary: 00000000.00000000
The keypad displays the setting as bit string (bit 0 is at
the rightmost position):
Value is bit-coded: ( = bit set)
Info
Bit 0 DI1 inverted
Inversion of digital input 1
Bit 1 DI2 inverted
Inversion of digital input 2
Bit 2 DI3 inverted
Inversion of digital input 3
Bit 3 DI4 inverted
Inversion of digital input 4
Bit 4 ... 14 Reserved
Bit 15 RFR inverted
Inversion of digital input RFR (controller enable)
DIx: polarity
C00114
EDIT
0
0
0
0
0
0
0
0
DI1
DI2
DI3
DI4
0
0
0
0
0
0
0
0
.
RFR
Digital outputs (DOx): Polarity
The polarity of each digital output of the device can be inverted via this bit field.
Setting range
(min. hex value | max. hex value)
Lenze setting
0x00
0xFF 0x00
Decimal: 0
Binary: 00000000
The keypad displays the setting as bit string (bit 0 is at
the rightmost position):
Value is bit-coded: ( = bit set)
Info
Bit 0 Relay inverted
Relay inversion
Bit 1 DO1 inverted
Inversion of digital output 1
Bit 2 ... 7 Reserved
DOx: polarity
C00118
EDIT
0
0
0
0
Relay
0
0
0
0
DO1
Analog voltage output (O1U): Gain
Setting range
(min. value | unit | max. value)
Lenze setting
-199.99
%
199.99 100.00 %
Analog voltage output (O1U): Offset
Setting range
(min. value | unit | max. value)
Lenze setting
-199.99
%
199.99 0.00 %