8adapting the application individually – Lenze E84AVSCx 8400 StateLine C User Manual
Page 56

8
Adapting the application individually
8.1
Function block interconnection of the "Actuating drive speed" application
56
Lenze · 8400 StateLine · Operating instructions · from Firmware V06.00 · DMS 1.2 EN · 12/2012 · TD05
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
Within the FB interconnection, the following modules are distinguished:
The following page shows the basic FB interconnection of the application.
Module type
Task
Examples
Function block
Implementation of a certain
function in the signal flow
L_NSet_1
Ramp generator
L_PCTRL_1
Process controller
L_MPot_1
Motor potentiometer
L_Or_1
Logic OR
L_OffsetGainP_1
Offset & gain
System block
Signal interface to inverter-
internal functions
LS_AnalogInput
Analog inputs
LS_AnalogOutput
Analog outputs
LS_DigitalInput
Digital inputs
LS_DigitalOutput
Digital outputs
LS_DriveInterface
Drive interface
LS_MotorInterface
Motor interface
Port block
Process data communication via
a fieldbus using a
communication module
LP_MciIn
Input ports
LP_MciOut
Output ports
Process data communication via
CAN on board
LP_CanIn1...3
Input ports
LP_CanOut1...3
Output ports
Application block
Block for a technology
application
LA_NCtrl
Actuating drive speed
LA_SwitchPos
Switch-off positioning
More information can be found in the reference manual for the 8400 StateLine in the
following chapters:
• Technology application TA "actuating drive..." Configuration parameters
• Working with the FB Editor