2 quick commissioning with the keypad, Quick commissioning with the keypad, 6commissioning – Lenze E84AVSCx 8400 StateLine C User Manual
Page 27

Lenze · 8400 StateLine · Operating instructions · from Firmware V06.00 · DMS 1.2 EN · 12/2012 · TD05
27
6
Commissioning
6.2
Quick commissioning with the keypad
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
6.2
Quick commissioning with the keypad
Target: For test and demonstration purposes, the load-free motor shall be rotated in best time with
an amount of wiring as little as possible and few settings.
Control via terminals or keypad?
For this simple application, you can choose between two drive control options:
• Terminal control (default setting):
• A setpoint potentiometer connected to the analog voltage input of the controller serves as
speed setpoint source.
• The control signals are selected via the digital inputs of the controller.
• Keypad control:
• The speed setpoint is selected with the keypad via C00728/3.
• The control signals are selected with the keypad via C00727/1...5.
Required commissioning steps
1. Wiring of power and control terminals.
• Refer to the mounting instructions supplied with the drive controller to find help on how to
correctly design the power connections to match the requirements of your device.
• A wiring example can be found in the chapter "
Connection/wiring of the controller
".
• For keypad control, only terminal X4/RFR of the control terminals (for controller enable) must
be wired:
2. Inhibit controller: Set terminal X4/RFR to LOW level or open contact.
3. Switch on voltage supply of the controller.
• Without motor operation: Connect external 24 V supply.
• With motor operation: Connect mains voltage.
If the green "DRV-RDY" LED is blinking and the red "DRV-ERR" LED is off, the controller is ready
for operation and commissioning can proceed.
Digital terminals (X4)
Name
Function
RFR
HIGH level
Controller enable
HIGHLOW
Reset error message
LOW level
(or open)
Controller inhibit
(
,
5)5
',
',
',
',
'2
*,2
*1',2
;
9
($96&[[[[[