7 diagnostics & troubleshooting, 1 led status displays for device status, Diagnostics & troubleshooting – Lenze E84AVSCx 8400 StateLine C User Manual
Page 44: Led status displays for device status, Informs abo, Sioning, 7diagnostics & troubleshooting
7
Diagnostics & troubleshooting
7.1
LED status displays for device status
44
Lenze · 8400 StateLine · Operating instructions · from Firmware V06.00 · DMS 1.2 EN · 12/2012 · TD05
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
7
Diagnostics & troubleshooting
7.1
LED status displays for device status
The control of the two LEDs "DRV-RDY" and "DRV-ERR" in the lower part on
the front of the inverter depends on the device status.
The meaning can be seen from the table below:
DRV-RDY DRV-ERR Description
Device status
(Display in C00137)
OFF
OFF
OFF or initialisation active
Init
OFF
Safe torque off is active
SafeTorqueOff
OFF
Device is ready to start
ReadyToSwitchOn
OFF
Device is switched on
SwitchedOn
OFF
Motor data identification/operation
OperationEnabled
The controller is ready to switch on, switched on or the operation is
enabled and a warning is indicated.
Fault active, quick stop
TroubleQSP
OFF
Trouble is active
Trouble
OFF
Fault is active
Fault
OFF
System fault is active
SystemFault
Legend
The symbols used for indicating the LED states have the following meaning:
LED is flashing once approx. every 3 seconds (slow flash)
LED is flashing once approx. every 1.25 seconds (flash)
LED is flashing twice approx. every 1.25 seconds (double flash)
LED is blinking every second
LED is permanently on
'595'<
&$1581
'59(55
&$1(55