tira54e1-a (2009-01) CDGxxxD.cp
If one of the bits 0…2 is set in the Exception Status, the current error can be read
in the "Exception Detail Alarm" parameter. The "Exception Detail Alarm" parameter
consists of a total of 8 bytes that inform on the error status of the gauge.
Due to the use of the extended error output format, these bytes have the following
structure:
Byte
no
Name
Description
Value
Common Exception Detail Alarm
0
Size
Number of subsequent bytes
used for description of the alarm
2
1 Detail
0
Error message
(simple, UINT8, 1 byte)
See table below
2 Detail
1
Error message
(simple, UINT8, 1 byte)
See table below
Device Exception Detail Alarm
3
Size
Number of subsequent bytes
used for description of the alarm
2
4
5
Detail Error
message
(array, UINT8, 2 bytes)
Sensor Alarm
(ID 103) of CDG
Transducer Block
(
→ section 12.1.3)
Manufacturer Exception Detail Alarm
6
Size
Number of subsequent bytes
used for description of the alarm
1
7 Detail
Error message
(simple, UINT8, 1 byte)
See table below
Bit
Common Exception Detail 0
Bit
Common Exception Detail 1
0
Internal diagnostic exception
0
0
1 Microprocessor
exception
1
0
2 EPROM
exception
2
0
3 EEPROM
exception
3
0
4 RAM
exception
4
0
5 Communications
exception
5
0
6
Internal real-time exception
6
0
7 0
7 0
Bit Manufacturer Exception Detail
0 Internal
communication
exception
1 Incompatible
software
2 0
3 0
4 0
5 0
6 0
7 0
7.1.12 Exception Detail Alarm
(ID 27)
Common Exception
Detail Alarm
Manufacturer Exception
Detail Alarm